163,System.IO.IOException: The process cannot access the file 'C:\inetpub\wwwroot\css\ExtFiles\CSS163DB.css' because it is being used by another process. at System.IO.__Error.WinIOError(Int32 errorCode, String maybeFullPath) at System.IO.FileStream.Init(String path, FileMode mode, FileAccess access, Int32 rights, Boolean useRights, FileShare share, Int32 bufferSize, FileOptions options, SECURITY_ATTRIBUTES secAttrs, String msgPath, Boolean bFromProxy) at System.IO.FileStream..ctor(String path, FileMode mode, FileAccess access, FileShare share, Int32 bufferSize, FileOptions options, String msgPath, Boolean bFromProxy) at System.IO.FileStream..ctor(String path, FileMode mode, FileAccess access, FileShare share, Int32 bufferSize, FileOptions options) at System.IO.StreamWriter..ctor(String path, Boolean append, Encoding encoding, Int32 bufferSize) at System.IO.StreamWriter..ctor(String path, Boolean append, Encoding encoding) at System.IO.File.WriteAllText(String path, String contents, Encoding encoding) at MasterPage.getStore() in C:\inetpub\wwwroot\MasterPage.master.vb:line 208 at MasterPage.Page_Init(Object sender, EventArgs e) in C:\inetpub\wwwroot\MasterPage.master.vb:line 18 caddy UTB60DP | 48WS Live Demo - Fastening Distributors
 
 

Search:

Universal Transient Barrier

UTB60DP

Caddy

(click image to enlarge)
Quick Overview
    • Compact design universal transient barrier - protection of low-voltage circuits and transducers
    • Separate plug and base design - hot swappable feature allows ease of module replacement
    • Compact, slimline two pair housing 12 mm wide
Interested in this item or want more information?
M-F 7:00AM - 5:00PM
Phone:
Email:

Can't find what you want? Give us a call and we can help you find it.
Details

Specifications :-

Part No.Part No. for EuropeDescription
UTB5DP 702886Nominal Voltage: 0 V to 3 VAC, 0 V to 5 VDC Voltage Protection Level (8/20µs): L-L 10 V @ 3 kA
UTB15DP 702887Nominal Voltage: 3 V to 10 VAC, 5 V to 15 VDC Voltage Protection Level (8/20µs): L-L 25 V @ 3 kA
UTB30DP 702888Nominal Voltage: 10 V to 21 VAC, 15 V to 30 VDC Voltage Protection Level (8/20µs): L-L 44 V @ 3 kA
UTB60DP 702889Nominal Voltage: 21 V to 42 VAC, 30 V to 60 VDC Voltage Protection Level (8/20µs): L-L 85 V @ 3 kA
UTB110DP 702891Nominal Voltage: 100 V to 110 VAC, 142 V to 154 VDC Voltage Protection Level (8/20µs): L-L 220 V @ 3 kA
UTB30DPS 702892Nominal Voltage: 24 V to 48 VAC, 12 V to 60 VDC Voltage Protection Level (8/20µs): L-L 220 V @ 3 kA
Additional Information
Manufacturer: Caddy
For More Information on the Universal Transient Barrier, [Click Here] to Link to Manufacturer Web Site
 